O&M 4.0: How Technology Is Transforming the Operation and Maintenance of Photovoltaic Plants
September 15, 2026
Why Does a Photovoltaic Installation Produce Less Energy Over Time?
November 17, 2026A photovoltaic installation is designed to generate electricity for decades, but this does not mean it will always produce the same amount of energy. Over time, solar modules, inverters and other components are exposed to environmental and electrical conditions that can affect their performance. In addition, factors such as soiling, shading, faulty connections and inadequate operation and maintenance can lead to production losses that sometimes go unnoticed for months.
Understanding why a photovoltaic installation produces less energy over time is essential for protecting the investment and maintaining its profitability. A decrease in energy generation is not always caused by the natural ageing of solar panels. In many cases, technical issues can be detected and corrected before they continue to affect production.
The degradation of solar modules is one of the main factors behind the gradual reduction in energy production. Throughout their service life, panels are exposed to ultraviolet radiation, temperature fluctuations, humidity, wind and other environmental factors that can affect their materials and components. Over time, this exposure can gradually reduce the modules’ ability to convert solar radiation into electricity. This is a normal process that should be considered during the installation’s design and when assessing its long-term performance.
However, degradation does not necessarily occur at the same rate in every panel. It depends on the technology used, the quality of the materials, climatic conditions and how the installation operates. Therefore, comparing current production with previous years requires taking into account variations in solar irradiation, temperature and availability. A reduction in generation that exceeds expectations may indicate that, in addition to natural degradation, other issues need to be investigated through a technical inspection and analysis of monitoring data.
Among the phenomena that can cause performance losses in photovoltaic modules are light-induced degradation, known as LID, and potential-induced degradation, or PID. LID occurs when certain types of photovoltaic cells experience an initial reduction in performance after being exposed to sunlight. Its magnitude depends on the manufacturing technology and the characteristics of the module. In some technologies, part of this loss stabilizes relatively early, so it should not be confused with continuous degradation throughout the entire service life.
PID, on the other hand, is associated with electrical and material-related mechanisms that can occur under specific voltage, temperature and humidity conditions. It can affect module performance and, in certain cases, cause significant losses if it is not identified in time. Detecting these phenomena requires analysing the installation’s electrical behaviour and, where necessary, carrying out specific tests. A drop in production alone is not enough to diagnose LID or PID: other possible causes must be investigated, and sufficient technical information is required.
Soiling is one of the most common causes of production losses in a photovoltaic installation. Dust, pollen, agricultural residues, pollution, bird droppings and other deposits can accumulate on the surface of modules, preventing some of the solar radiation from reaching the cells. The impact depends on the plant’s location, panel tilt, surrounding environment and weather conditions. An installation located near industrial areas, agricultural land or places with high levels of airborne dust may require a different cleaning strategy from a plant in a less exposed environment.
Rain can help remove some dirt, but it does not guarantee complete cleaning. Certain residues remain attached to the surface or accumulate in specific areas of the module, causing persistent losses. For this reason, cleaning should be incorporated into the operation and maintenance plan and adapted to the actual conditions of each installation. Production monitoring and inspections help determine when cleaning may be necessary, avoiding both insufficient cleaning and unnecessary interventions.
Although solar modules generally have a long service life, photovoltaic inverters contain electronic components that can be affected by operating conditions and ageing. Their condition directly influences the plant’s ability to convert and deliver the electricity generated. Component ageing, ventilation problems, high temperatures, recurring alarms or internal faults can reduce inverter availability and performance. In some cases, the equipment may stop working completely; in others, it may experience limitations or intermittent interruptions that are less obvious.
Reviewing alarms, operating histories, temperatures and production data helps identify these situations. It is also important to check that ventilation and cooling systems are in good condition and that the equipment operates within the manufacturer’s specifications. In installations with several inverters, comparing their performance can help identify deviations. If similar units show persistent differences under comparable conditions, it is worth investigating whether a technical issue or specific limitation is responsible.
Electrical connections are another critical element in maintaining the performance of a photovoltaic installation. Connectors, cabling, terminals and electrical panels are exposed to environmental conditions and stresses that can cause deterioration over time. A faulty connection can increase electrical resistance, cause abnormal heating and lead to energy losses. In more serious situations, it can pose a safety risk to the installation.
Visual inspections, electrical checks and thermography can help identify certain problems before they develop into major failures. Hotspots detected during a thermographic inspection should be assessed by qualified personnel, as they can have different causes and require an appropriate diagnosis. An effective O&M strategy should include the inspection of connectors, cabling, electrical panels and protection systems, following applicable safety procedures and technical recommendations.
Shading on photovoltaic modules can significantly reduce their energy production. Although the initial design takes existing obstacles into account, the surrounding environment can change over time. The growth of trees and vegetation, the construction of new structures or the installation of equipment on an industrial rooftop can create shadows that were not present when the plant was commissioned.
These shadows can affect the output of individual modules and, depending on the electrical configuration, may also influence the performance of other panels connected to the same circuit. For this reason, it is important to periodically review the installation’s surroundings and check whether new obstacles have appeared. Vegetation management, rooftop inspections and production-pattern analysis can help identify these losses and assess appropriate corrective measures.
A photovoltaic installation can continue operating for years without certain issues being detected. However, the fact that equipment is still generating electricity does not necessarily mean it is operating under optimal conditions. A lack of periodic inspections can allow minor defects to develop, dirt to remain accumulated or monitoring failures to go unnoticed. It can also delay the detection of problems involving inverters, connections, structures or protection systems.
Photovoltaic operation and maintenance makes it possible to establish a strategy for supervising equipment condition, analysing performance and planning the necessary interventions. Its objective is not only to repair failures, but also to reduce avoidable losses and keep the installation operating under appropriate conditions.
Monitoring is essential for understanding how a photovoltaic plant’s production evolves. Comparing the energy generated across different periods is useful, but it must take into account factors such as solar irradiation, temperature, weather conditions and operating hours. Indicators such as the Performance Ratio (PR), availability and comparisons between equipment help identify deviations that may be associated with performance losses.
Data analysis makes it possible to detect sudden drops, persistent differences between inverters or abnormal behaviour in specific parts of the installation. When combined with visual inspections, thermography and electrical checks, it provides a more complete diagnosis. Advanced analytics and artificial intelligence can also help identify abnormal patterns and prioritize incidents. However, alerts must be interpreted in the context of the plant’s characteristics and verified through a technical inspection when necessary.
When a plant produces less energy than expected, the first step is to identify the source of the losses. Replacing equipment or making major investments is not always necessary. In some cases, cleaning, correcting shading, repairing a connection or resolving an inverter issue can recover part of the energy that was being lost. For installations that have been operating for many years, it may also be worth assessing the overall condition of the components and determining whether specific refurbishment or repowering measures make technical and economic sense.
The key is to base decisions on reliable data, appropriate inspections and an assessment of actual losses. A well-structured operation and maintenance plan makes it possible to prioritize interventions, reduce response times and prevent problems from accumulating.
Ultimately, a photovoltaic installation may produce less energy over time because of natural module degradation, but also because of soiling, phenomena such as LID or PID, inverter ageing, faulty connections, new sources of shading or inadequate maintenance. Correctly identifying each cause is essential to preventing unnecessary losses.
Photovoltaic operation and maintenance is a key tool for protecting investment, maintaining availability and optimizing long-term production. Through continuous monitoring, technical inspections, and preventive and predictive maintenance, asset owners can gain a better understanding of their installations and make informed decisions to preserve performance throughout their service life..